Modifying formulas to skip rows between subgroups

Some text files, such as those generated by many coordinate measuring machines (CMMs), include a fixed number of rows of text between the rows of SPC data.

You can use the Template Wizard to bypass those extra rows.  In the Repeat column, add one FREAD command for each extra text row in your file.

If it is possible to reach the end of the file from this template cell, you should also check for the end of the file using the FEOF command.  You can find an example of this formula in the Read column.