This tab is available for Scripted SPC Retrievals and Scripted DMS Retrievals.
On this tab you must select or create a Python script that reads the data from your external source, and then uses the retrspc.external or retrdms.external commands to translate that data correctly for GainSeeker.
After you have created and debugged the Python script in the Python Script Editor, choose that script for this Retrieval.
For an SPC Retrieval, GainSeeker will perform a separate statistical analysis of the data retrieved for each standard.
For a DMS Retrieval, you also need to choose a Group statistics/data by option:
All in one group – With this setting, GainSeeker will provide:
a single set of statistics (if selected) for all of the selected standards and/or processes
a single set of Pareto details (if selected) for all of the selected standards and/or processes
a single set of DPU details (if selected) for all of the selected standards and/or processes
a single set of OEE details (if selected) for all of the selected standards and/or processes
Process – With this setting, GainSeeker will provide:
a separate set of statistics (if selected) for each selected process
a separate set of Pareto details (if selected) for each selected process
a separate set of DPU details (if selected) for each selected process
a separate set of OEE details (if selected) for each selected process
Part Number – With this setting, GainSeeker will provide:
a separate set of statistics (if selected) for each selected Part Number
a separate set of Pareto details (if selected) for each selected Part Number
a separate set of DPU details (if selected) for each selected Part Number
a separate set of OEE details (if selected) for each selected Part Number
Part Number/Process – With this setting, GainSeeker will provide:
a separate set of statistics (if selected) for each selected DMS standard (Part Number + process)
a separate set of Pareto details (if selected) for each selected DMS standard (Part Number + process)
a separate set of DPU details (if selected) for each selected DMS standard (Part Number + process)