DMS Chart Options

The DMS Chart Options window lets you configure charts to display on the current sub-inspection. For information on opening this window, see Setting charts to display in inspections.

 

Contents  [Hide]

 

Step 1: Select DMS standards for the retrieval

If you want this sub-inspection to chart multiple standards with the same chart types and chart settings (date period, filter, statistical settings, etc.), you can use this step to select all those standards at once – beginning with the Part Number Source:

When finished selecting standards, click Next Step.

Step 2: Select chart types

Select the DMS chart types you want to display, and then click Next Step.

Step 3: Modify settings for the selected charts

Choose retrieval and statistical settings for the standards and charts you have selected. You can also specify a Chart skin (created in the GainSeeker Charts module) that changes display options for these charts. When finished, click Save and Close.  

Tip: If desired, you can configure the charts with a special filter for data that matches traceability values in this inspection:

Filtering for inspection traceability values

In some cases, you may wish to filter the chart for a traceability value that was entered in this inspection – by a Traceability test, Planned Inspection, or Formula test (using inspect.cursubi.trace(idx).value  or inspect.settracevalue Python commands).

For example, you might wish to filter for:

      • a Lot number that the user enters during data entry

      • a Machine ID that you preset with a Planned Inspection or Formula test

To filter for such a traceability value – which may vary from one data entry session to the next – you must create a saved filter that looks for a blank value in that traceability field, such as this example which filters for the current Cavity number:

Best practice: For this type of traceability filter, best practice is to set this traceability value before launching the sub-inspection that filters charts for that value. This is most easily accomplished by:

      • requiring the user to Submit the traceability value in a Traceability test on a previous sub-inspection

      • removing this traceability field from the inspection and using a Planned Inspection to set the traceability value

      • removing this traceability field from the inspection and using a Formula test to set the traceability value with the Python command inspect.settracevalue. (You can actually execute this Formula on the same sub-inspection as the filtered charts by setting the FormulaMode property to Pre.)

The reason for this recommended practice is that the filter can only access a traceability value after that value has been submitted.

If the traceability value is not set before the sub-inspection with the filter is launched, the charts will be filtered for a blank value in this traceability field until the sub-inspection is submitted with the new traceability value.

When new charts are opened and updated during an inspection

When you use the ChartOptionsDMS property of a sub-inspection to set up charts, the timing for creating and updating those charts depends on how the standard or process for those charts is defined.

Note: When the inspector submits the sub-inspection data, all charts open in the right side panel refresh for that sub-inspection. If you have multiple charts or charts containing a lot of data open in the panel, this could prove time consuming.

Preset DMS standards or processes

When standards or processes are selected using one of these methods, the corresponding chart will be created immediately when the sub-inspection opens:

      • When setting the sub-inspection property ChartOptionsDMS, the Part Number Source is set to Select standard from list

      • When setting the sub-inspection property ChartOptionsDMS, the Part Number Source is set to Use Inspection Process, and one of the following criteria is met:

        • The Inspection has the Process property set to a particular process

        • A Planned Inspection is used to select a different process for the Inspection

      • When setting the sub-inspection property ChartOptionsDMS, the Part Number Source is set to Use Inspection Part Number and Process, and one of the following criteria is met:

        • This sub-inspection does not contain a DMS Standard test, because the DMS Standard is set by a previous sub-inspection

        • This sub-inspection contains a DMS Standard test with the DMSStandard property set to a particular standard

          Please note: If the DMSStandard property contains a value that does not match an existing DMS standard, the inspection will still generate a chart for that "value".

        • This sub-inspection contains a DMS Standard test, and a Planned Inspection is used to select a different DMS standard for this sub-inspection

        • This sub-inspection contains a DMS Standard test, and it also contains a Formula test with the FormulaMode property set to Pre and the PythonScript property set to a script that uses the inspect.cursubi.dmspart(idx).partnumber command to set a different standard

When the user submits or re-opens the sub-inspection, these charts will be updated to include the most recently-entered data.

DMS standards selected by the data entry user

When all of the following criteria are met, the chart for a standard will be created immediately after the data entry user selects the standard:

      • When setting the sub-inspection property ChartOptionsDMS, the Part Number Source is set to Use Inspection Part Number and Process

      • This sub-inspection contains a DMS Standard test with the DMSStandard property left blank

If the user later selects a different standard for the same DMS Standard test, a new chart will be added for the new standard without removing the chart for the previous standard.

When the user submits or re-opens the sub-inspection, these charts will be updated to include the most recently-entered data.

When charts are closed during an inspection

Any of the following methods will close all charts that are currently open in an inspection:

Sending emails with charts during an inspection