File Path |
SPC |
DMS |
Table Names |
Supporting files 1 |
Table/File Contents |
Config_path= in Cms.ini Applies to entire GainSeeker deployment |
X |
X |
HSICFG, |
|
Configuration settings, roles, and user names |
X |
X |
*.stat |
Custom Statistics *.stat files contain Custom Statistics exported from GainSeeker See also: configuration-specific HSISCRIPTS table |
||
X |
X |
AuditTrl |
Audit.prf |
Audit trail *.prf file contains legacy audit trail table column settings |
|
X |
|
|
Mtb_spc.txt |
Commands to Send To MINITAB via COM |
|
|
X |
|
Mtb_dms.txt |
Commands to Send To MINITAB via COM |
|
X |
|
|
Mcht_cmd.txt |
List of commands for use with MINITAB charts |
|
X |
|
|
Minitab.db |
MINITAB charts configured for use in SPC Charts and Reports |
|
X |
|
|
WebOut.dat |
HTML format file for legacy SPC modules and Enterprise Dashboard |
|
X |
X |
|
System and conversion information |
||
X |
|
|
*.gpn |
GagePort configuration files |
|
X |
X |
|
*.vsf |
Version Verify files |
|
X |
X |
|
Btrtools.log |
BtrTools log file |
|
No Path (database-only) Different variations of these table names can be set for different configurations. |
X |
X |
HSIRPT |
*.rdlx *.dlx *.dbz *.dbx *.dbrx *.dtx *.txt *.cpz *.cpx *.xml |
Dashboards and Dashboard Retrievals, Desktops, Chart Skins, Dynamic Reports, Inspections, Device Profiles, Priority Lists, Column and Detail Reports, and .Launch settings *.rdlx files contain exported Dynamic Reports *.dlx files contain settings exported from the .Launch module *.dbz files contain full Dashboards exported from the GainSeeker Charts module versions 8.5 and newer (Dashboard Designs, Retrievals, Filters, etc.) *.dbx files contain Dashboard Designs exported from the GainSeeker Charts module prior to version 8.5 *.dbrx files contain Dashboard Retrievals exported from the GainSeeker Charts module *.dtx files contain Desktops exported from the GainSeeker Charts module *.txt files contain exported Data Column Reports, Data Grid Header and Detail Reports, Chart Skins, and DMS Detail Reports used by the GainSeeker Charts module *.cpz files contain full Inspections exported from GainSeeker versions 8.5 and newer (Inspection, Device Profiles, and Python Designs) *.cpx files contain exported Inspections (versions 8.3 and 8.4) *.xml files contain exported Inspections (prior to version 8.3) |
X |
X |
|
Table stores Unique IDs for GainSeeker Inspections |
||
X |
X |
|
Control table Table is used by the PC Collect module but can also be used in templates and elsewhere as a generic control table |
||
SPC Standards Different variations of these table names can be set for different configurations. |
X |
|
Vstds |
Vstdfile.prf, |
SPC standards *.prf files contain report formats for printing standards and process specifications |
X |
|
VPri |
|
Priority list of SPC standards |
|
X |
|
|
*.std, |
Import/export files for SPC standards and process specifications *.xml and *.ps are file formats from legacy SPC Standard Utility module |
|
SPC Data Different variations of these table names can be set for different configurations. The SPC Data table should correspond to a single instance of the tables for SPC Event, SPC Cause, and SPC Action Taken. These tables use an internal code or number to log these values, so having two configurations that point to the same Data table but different corrective action tables will produce unexpected results. |
X |
|
Vdata |
De_mtb.prf, |
SPC data *.prf files contain data table column settings for displaying in SPC Data Entry and legacy SPC Charts and Reports and for sending to MINITAB |
X |
|
Vdat_aux |
|
Additional SPC data |
|
X |
|
Vmon |
Dt_both.prf, |
SPC monitor *.prf files contain data table column settings for the three types of Monitor windows |
|
X |
|
Vmon_aux |
|
SPC monitor |
|
X |
|
Vnote |
Note_spc.prf |
SPC notes *.prf file contains report format for printing notes from legacy Note Manager module |
|
X |
X |
DashSW |
*.eds, *.edf |
Legacy Enterprise Dashboard windows *.edf files contain DMS statistical filter definition |
|
X |
X |
DashDT |
*.edd |
Legacy Enterprise Dashboard desktops |
|
X |
X |
DashRet |
*.edr |
Legacy Enterprise Dashboard retrievals |
|
X |
|
|
dt_dbf.prf |
Column settings used when viewing failures from real-time failure dashboards in the legacy Enterprise Dashboard module |
|
X |
|
|
dt_dbd.prf |
Data table column settings for SPC dashboards in the legacy Enterprise Dashboard module |
|
|
X |
|
dt_ddbd.prf |
Data table column settings for DMS dashboards in the legacy Enterprise Dashboard module |
|
X |
|
Session SessionList |
*.dss |
SPC stored sessions |
|
X |
|
Filter |
*.vf |
SPC filters |
|
X |
|
Sfilter |
*.sf |
SPC statistical filters |
|
X |
|
Mfilter |
*.mf |
SPC monitor filters |
|
X |
|
Report |
*.rp |
SPC report formats in the legacy SPC Charts and Reports module |
|
X |
|
Statlist |
*.st |
SPC statistics lists |
|
X |
|
Desktop |
*.dt, *.dtm |
SPC desktops in the legacy SPC Charts and Reports module |
|
X |
|
VPri_Dt |
|
SPC desktop priority list for the legacy SPC Charts and Reports module |
|
X |
X |
|
RTF*.rtf, |
Desktop Notes in the legacy SPC Charts and Reports and Enterprise Dashboard modules |
|
X |
X |
|
DTNote.rtf, |
Default Desktop Note for the legacy SPC Charts and Reports and Enterprise Dashboard modules |
|
X |
|
|
Spc_dt.gmm, |
MINITAB macro files |
|
Different variations of these table names can be set for different configurations. |
X |
|
Template |
*.dev, *.gpc |
SPC data entry templates |
DMS Standards Different variations of these table names can be set for different configurations. |
|
X |
Dstds |
DStds.prf |
DMS standards *.prf file contains legacy report format for printing standards |
|
X |
Dproc |
Dproc.prf |
DMS process information *.prf file contains legacy report format for printing process specifications |
|
|
X |
Dprocdl |
|
DMS process defect list |
|
|
X |
Dmdl |
|
DMS master defect list |
|
|
X |
DPri |
|
Priority list of DMS standards |
|
DMS Data Different variations of these table names can be set for different configurations. The DMS Data table should correspond to a single instance of the tables for DMS Event and DMS Master Defect List. These tables use an internal code or number to log these values, so having two configurations that point to the same data table but different Event and/or defect master list table will produce unexpected results. |
|
X |
Ddata |
Dt_dms.prf, |
DMS data *.prf files contain data table column settings for displaying in legacy DMS Charts and Reports and DMS Data Entry modules, as well as the defect detail table column settings for these legacy modules |
|
X |
Ddat_aux |
|
Additional DMS data |
|
|
X |
Dnote |
Note_dms.prf |
DMS notes *.prf file contains report format for printing notes from legacy Note Manager module |
|
|
X |
Dstats |
*.st |
DMS statistics lists |
|
|
X |
Dfilter |
*.df |
DMS filters |
|
|
X |
Ddt |
*.dt |
DMS desktops in legacy DMS Charts and Reports module |
|
|
X |
DPri_Dt |
|
DMS desktop priority list for the legacy DMS Charts and Reports module |
|
|
X |
|
RTF*.rtf, |
Desktop Notes in legacy DMS Charts and Reports module |
|
|
X |
|
DTNote.rtf, |
Default Desktop Note in legacy DMS Charts and Reports module |
|
|
X |
|
Format.rpt |
DMS Report Writer report format in legacy DMS Charts and Reports module |
|
|
X |
|
Dms_dt.gmm, |
MINITAB macro files |
|
Traceability Different variations of these table names can be set for different configurations. |
X |
X |
Trace1 |
|
Traceability lists 1 - 6 |
X |
X |
TraceMst |
|
Traceability 7-48 |
|
X |
|
TrPriMst |
|
Traceability priority list |
|
X |
|
EventCA |
|
SPC Event list |
|
X |
|
Cause |
|
SPC Cause list |
|
X |
|
Action |
|
SPC Action Taken list |
|
|
X |
Event |
|
DMS event list |
|
X |
|
SchFile |
*.psu |
SPC planned session names |
|
X |
|
Plan_Val |
|
SPC planned session contents |
|
X |
|
Plan_Aux |
|
SPC planned session contents |
|
X |
|
Rtmsg.prf |
*.prf file supports user-defined text for SPC real-time failure messages |
||
X |
X |
|
ChtFonts.prf, |
*.prf files support font and color settings for charts and tables in SPC Data Entry and legacy modules |
|
Import/Export Different variations of these table names can be set for different configurations. |
X |
|
|
*.iet |
SPC templates from legacy Import/Export module |
|
X |
|
*.ied |
DMS templates from legacy Import/Export module |
|
Archive Different variations of these table names can be set for different configurations. |
X |
|
|
V*.arc, |
SPC archive files from legacy Import/Export module |
|
X |
|
D*.arc |
DMS archive files from legacy Import/Export module |
|
X |
X |
|
*.xml, |
Export files for GainSeeker data *.csv and *.qsv are file formats from legacy I module |
|
User Documents 1 Different variations of these table names can be set for different configurations. |
|
|
|
|
GainSeeker Collect Mobile App stores photos and videos in this folder |
Different variations of these table names can be set for different configurations. |
X |
X |
*.fiw *.pydash |
Python scripts for dashboards, PC Collect data entry, and scripted External Data *.fiw files contain File Import Configuration files created in GainSeeker Inspections *.pydash files contain Python Designs exported from GainSeeker See also: master HSISCRIPTS table |
|
|
|
|
|
GainSeeker Collect Mobile App retrieves photos used in an Inspection from this folder |
|
(For example, C:\Windows\ or |
X |
X |
|
Cms.ini |
Workstation-specific settings |
X |
X |
|
*.prf |
When you choose to "save as default... for this workstation only", a .prf file is created or updated in this folder. See above for individual names of .prf files. |
|
ProgramData\Hertzler Systems\ folder (For example, C:\ProgramData\Hertzler Systems\ or |
X |
X |
|
Workstation-specific settings |
|
LocalAppData\Hertzler_Systems\ folder (For example, C:\Users\user_name\AppData\Local\Hertzler_Systems\) |
X |
X |
|
Collectui.settings Gscharts.settings Inspectioneditor.settings Launchpad.settings |
Workstation-specific settings |
path referenced by Redirect.hsi |